-- This file was included in WWP MIB release 04-16-00-0047
 --
 -- CIENA-CES-TIME-SYNC-MIB.my
 --

 CIENA-CES-TIME-SYNC-MIB DEFINITIONS ::= BEGIN

 IMPORTS
    Integer32, Unsigned32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
        FROM SNMPv2-SMI
    DisplayString, TEXTUAL-CONVENTION
        FROM SNMPv2-TC
    cienaCesConfig, cienaCesNotifications 
        FROM CIENA-SMI
    CienaGlobalState
        FROM CIENA-TC
    cienaGlobalSeverity, cienaGlobalMacAddress
        FROM CIENA-GLOBAL-MIB
    cienaCesModuleSlotName
        FROM CIENA-CES-MODULE-MIB;


 cienaCesTimeSyncMIB MODULE-IDENTITY
        LAST-UPDATED "201601210000Z"
        ORGANIZATION "Ciena, Inc"
        CONTACT-INFO
            "   Mib Meister
            115 North Sullivan Road
            Spokane Valley, WA 99037
                USA
                Phone:  +1 509 242 9000
            Email:  support@ciena.com"
        DESCRIPTION
            "This MIB module defines objects and associated notifications
             for the System Timing feature."

        REVISION
            "201601210000Z"
        DESCRIPTION
            "Updating the description of cienaCesSyncInputPUStateChangeNotification,
            cienaCesSyncInputProtectionGroupStateChangeNotification and
            cienaCesSyncModuleSlotClockStateChangeNotification."

        REVISION
            "201509280000Z"
        DESCRIPTION
            "Adding cienaCesInputPUGPSBITSSignalSsmLocation to cienaCesSyncInputProtectionUnitEntry.
            Adding 'sa8(6)' into cienaCesOutputBITSSignalSsmlocation."

        REVISION
            "201504200000Z"
        DESCRIPTION
            "Adding 'unusable' to SyncRefOperationalStatus."

        REVISION
            "201504100000Z"
        DESCRIPTION
            "Updating cienaCesSyncInputProtectionGroupStateChangeNotification trap."

        REVISION
            "201503190000Z"
        DESCRIPTION
            "Updating cienaCesSyncModuleSlotClockStateChangeNotification trap."

        REVISION
            "201503110000Z"
        DESCRIPTION
            "Aligning SyncRefOperationalStatus."

        REVISION
            "201502040000Z"
        DESCRIPTION
            "Updating SyncBITSSignalFormat."

        REVISION
            "201501230000Z"
        DESCRIPTION
            "Adding cienaCesInputPGOperationalQualityLevel object."

        REVISION
            "201501070000Z"
        DESCRIPTION
            "Adding cienaCesSyncModuleSlotClockStateChangeNotification trap."
             
        REVISION
            "201404250000Z"
        DESCRIPTION
            "Adding cienaCesSyncPTPOutputTimestampMode object."

        REVISION
            "201403250000Z"
        DESCRIPTION
            "Aligning SyncRefOperationalStatus and cienaCesInputPGOperationalStatus with current implementation."

        REVISION
            "201312030000Z"
        DESCRIPTION
            "Adding PTP boundary clock support."

        REVISION
            "201305170000Z"
        DESCRIPTION
            "Adding 'warmup' status to SyncRefOperationalStatus."

        REVISION
            "201305070000Z"
        DESCRIPTION
            "Adding TDM reference support."

        REVISION
            "201304200000Z"
        DESCRIPTION
            "Adding 'signalfailure' status to SyncRefOperationalStatus."

        REVISION
            "201304160000Z"
        DESCRIPTION
            "Adding PTP and GPS support. Adding cienaCesInputPGTimingType to
            the cienaCesSyncInputProtectionGroupTable. Adding 'notready' status
            to SyncRefOperationalStatus."

        REVISION
            "201304080000Z"
        DESCRIPTION
            "Deprecated cienaCesInputPGPreferredReference and cienaCesInputPGState."

        REVISION
            "201303080000Z"
        DESCRIPTION
            "Added Override-priority parameter for input reference."

        REVISION
            "201206200000Z"
        DESCRIPTION
            "Initial version."

        ::= { cienaCesConfig 28 }

 --
 -- Textual convention
 --

 SsmStratumLevel ::= TEXTUAL-CONVENTION
     STATUS       current
     DESCRIPTION  "International and North American SSM Values"
     SYNTAX       INTEGER 
                  {
                     unknown(1),
                     prc(2), 
                     ssua(3),
                     ssub(4),
                     sec(5),
                     dnu(6),
                     prs(7),
                     stu(8),
                     st2(9),
                     tnc(10),
                     st3e(11),
                     st3(12),
                     smc(13),
                     st4(14),
                     dus(15),
                     prov(16)
                  }

 SyncInterfaceProtocol ::= TEXTUAL-CONVENTION
     STATUS       current
     DESCRIPTION  "Interface protocol of an input/output reference."
     SYNTAX       INTEGER
                  {
                     unknown(1),
                     bits(2),
                     synce(3),
                     ptp(4),
                     gps(5),
                     tdm(6)
                  }

 SyncBITSSignalMode ::= TEXTUAL-CONVENTION
     STATUS       current
     DESCRIPTION  "Station Clock BITS signal mode."
     SYNTAX       INTEGER
                  {
                     modeunknown(1),
                     modet1(2),
                     modee1(3),
                     modej1(4),
                     mode2048khz(5),
                     mode64kcc(6),
                     mode6312khz(7)
                  }

 SyncBITSSignalFormat ::= TEXTUAL-CONVENTION
     STATUS       current
     DESCRIPTION  "Station Clock BITS signal format.  Esf and sf are applied to t1 signal
                   only where as ccs and cas are applied to e1 signal."
     SYNTAX       INTEGER
                  {
                     unknown(1),
                     cas(2),
                     cascrc(3),
                     esf(4),
                     fas(5),
                     fascrc(6),
                     sf(7),
                     e1crc(8),
                     e1nocrc(9)
                  }

 SyncBITSSignalEncoding ::= TEXTUAL-CONVENTION
     STATUS       current
     DESCRIPTION  "Encoding method used on T1/E1 BITS signal."
     SYNTAX       INTEGER
                  {
                     unknown(1),
                     b8zs(2),
                     ami(3),
                     hdb3(4)
                  }

 SyncRefOperationalStatus ::= TEXTUAL-CONVENTION
     STATUS       current
     DESCRIPTION  "Operational status of an input/output reference."
     SYNTAX       INTEGER
                  {
                     unknown(1),
                     active(2),
                     selected(3),
                     lossofsignal(4),
                     lossofframe(5),
                     alarmindicationsignal(6),
                     hardwarefault(7),
                     hardwarenotconfigured(8),
                     qlbelowthreshold(9),
                     rxtimeout(10),
                     notauthenticated(11),
                     loopbacktx(12),
                     loopbackrx(13),
                     linkflap(14),
                     notready(15),
                     signalfailure(16),
                     warmup(17),
                     qlnotconfigured(18),
                     noconnectivity(19),
                     unsupportedhardware(20),
                     unusable(21)
                  }

 SyncTimingType ::= TEXTUAL-CONVENTION
     STATUS       current
     DESCRIPTION  "The timing domain; frequency, phase or time of day."
     SYNTAX       INTEGER
                  {
                     unknown(1),
                     frequency(2),
                     phase(3),
                     tod(4),
                     phaseandtod(5)
                  }

 SyncPTPRatePps ::= TEXTUAL-CONVENTION
     STATUS       current
     DESCRIPTION  "The PTP rate in pps."
     SYNTAX       INTEGER
                  {
                     unknown(1),
                     rate1over16pps(2),
                     rate1over8pps(3),
                     rate1over4pps(4),
                     rate1over2pps(5),
                     rate1pps(6),
                     rate2pps(7),
                     rate4pps(8),
                     rate8pps(9),
                     rate16pps(10),
                     rate32pps(11),
                     rate64pps(12),
                     rate128pps(13)
                  }

 SyncGPSFreqClock ::= TEXTUAL-CONVENTION
     STATUS       current
     DESCRIPTION  "The frequency of the clock for a GPS input/output reference,
                   set when the reference is configured with a clock mode of frequency."
     SYNTAX       INTEGER
                  {
                     unknown(1),
                     clock10mhz(2),
                     clock2048khz(3),
                     clock1544khz(4)
                  }

 SyncPTPEncapType ::= TEXTUAL-CONVENTION
     STATUS       current
     DESCRIPTION  "The PTP encapsulation type."
     SYNTAX       INTEGER
                  {
                     unknown(1),
                     udpoveripv4(2),
                     udpoveripv6(3),
                     ieee802dot3(4)
                  }

 --
 -- Node definitions
 --

 cienaCesTimeSyncMIBObjects   OBJECT IDENTIFIER ::= { cienaCesTimeSyncMIB 1 }
 cienaCesTimeSyncObjects      OBJECT IDENTIFIER ::= { cienaCesTimeSyncMIBObjects 1 }

 -- Notifications   
 cienaCesTimeSyncMIBNotificationPrefix  OBJECT IDENTIFIER ::=  { cienaCesNotifications 28 } 
 cienaCesTimeSyncMIBNotifications       OBJECT IDENTIFIER ::=  { cienaCesTimeSyncMIBNotificationPrefix 0 }


--
-- Global objects 
--
    
 cienaCesSyncAdminState OBJECT-TYPE
     SYNTAX      CienaGlobalState
     MAX-ACCESS  read-only
     STATUS      current
     DESCRIPTION
         "Globally enable/disable Sync"
    ::= { cienaCesTimeSyncObjects 1 }

 cienaCesSyncOptionType OBJECT-TYPE
    SYNTAX      INTEGER
                {
                   unknown(1),
                   option1(2),
                   option2(3)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Indication of which set of SSM values being used.  Option 1 is
         for International standard and Option 2 is for North American."
    ::= { cienaCesTimeSyncObjects 2 }

 cienaCesSyncRevertiveMode OBJECT-TYPE
    SYNTAX      INTEGER
                {
                   unknown(1),
                   revertive(2),
                   nonrevertive(3)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Revertive mode."
    ::= { cienaCesTimeSyncObjects 3 }

 cienaCesSyncWaitToRestoreTimer OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "User configured timer for a timing reference source to wait
         before transitioning from bad to good clock signal."
    ::= { cienaCesTimeSyncObjects 4 }

 cienaCesSyncHoldoverInterval OBJECT-TYPE
   SYNTAX      INTEGER
               {
                  unknown(1),
                  indefinite(2),
                  twentyfourhours(3)
               }
   MAX-ACCESS  read-only
   STATUS      current
   DESCRIPTION
       "User configured interval after which holdover quality level changes."
   ::= { cienaCesTimeSyncObjects 10 }

--
-- SyncInputProtectionGroupTable
--

cienaCesSyncInputProtectionGroupTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF CienaCesSyncInputProtectionGroupEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table of protection groups for input timing reference."
    ::= {  cienaCesTimeSyncObjects 5 }

cienaCesSyncInputProtectionGroupEntry OBJECT-TYPE
    SYNTAX      CienaCesSyncInputProtectionGroupEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry in this table represents information on a protection
         group for input timing reference"
    INDEX       { cienaCesInputPGEntityId }
    ::= { cienaCesSyncInputProtectionGroupTable 1 }

CienaCesSyncInputProtectionGroupEntry ::= SEQUENCE {
        cienaCesInputPGEntityId                  Integer32,
        cienaCesInputPGEntityName                DisplayString,
        cienaCesInputPGPreferredReference        DisplayString,
        cienaCesInputPGSelectedReference         DisplayString,
        cienaCesInputPGForcedReference           DisplayString,
        cienaCesInputPGThresholdQualityLevel     SsmStratumLevel,
        cienaCesInputPGState                     CienaGlobalState,
        cienaCesInputPGStateDuration             DisplayString,
        cienaCesInputPGReferenceSwitchCount      Unsigned32,
        cienaCesInputPGOperationalStatus         INTEGER,
        cienaCesInputPGTimingType                SyncTimingType,
        cienaCesInputPGOperationalQualityLevel   SsmStratumLevel
        }

 cienaCesInputPGEntityId OBJECT-TYPE
    SYNTAX      Integer32 (1)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The unique identifier of this input protection group."
    ::= { cienaCesSyncInputProtectionGroupEntry 1 }

 cienaCesInputPGEntityName OBJECT-TYPE
    SYNTAX      DisplayString (SIZE (1..31))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The unique name of this input protection group."
    ::= { cienaCesSyncInputProtectionGroupEntry 2 }

 cienaCesInputPGPreferredReference OBJECT-TYPE
    SYNTAX      DisplayString (SIZE (1..31))
    MAX-ACCESS  read-only
    STATUS      deprecated
    DESCRIPTION
        "Preferred timing reference source, configured by users."
    ::= { cienaCesSyncInputProtectionGroupEntry 3 }

 cienaCesInputPGSelectedReference OBJECT-TYPE
    SYNTAX      DisplayString (SIZE (1..31))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "System selected timing reference source."
    ::= { cienaCesSyncInputProtectionGroupEntry 4 }

 cienaCesInputPGForcedReference OBJECT-TYPE
    SYNTAX      DisplayString (SIZE (1..31))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "System was forced to used this timing reference source."
    ::= { cienaCesSyncInputProtectionGroupEntry 5 }

 cienaCesInputPGThresholdQualityLevel OBJECT-TYPE
    SYNTAX      SsmStratumLevel
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Specified Quality Level threshold for a reference source
         being selected."
    ::= { cienaCesSyncInputProtectionGroupEntry 6 }

 cienaCesInputPGState OBJECT-TYPE
    SYNTAX      CienaGlobalState
    MAX-ACCESS  read-only
    STATUS      deprecated
    DESCRIPTION
        "Configured state of this protection group."
    ::= { cienaCesSyncInputProtectionGroupEntry 7 }

 cienaCesInputPGStateDuration OBJECT-TYPE
    SYNTAX      DisplayString (SIZE (1..31))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Duration since the system entered current state."
    ::= { cienaCesSyncInputProtectionGroupEntry 8 }

 cienaCesInputPGReferenceSwitchCount OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of timing reference switching since the system stared up."
    ::= { cienaCesSyncInputProtectionGroupEntry 9 }

 cienaCesInputPGOperationalStatus OBJECT-TYPE
    SYNTAX      INTEGER
                {
                   unknown(1),
                   freerun(2),
                   holdover(3),
                   locked(4),
                   acquiringlock(5),
                   holdoverexpired(6)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Operational status of this protection group."
    ::= { cienaCesSyncInputProtectionGroupEntry 10 }

 cienaCesInputPGTimingType OBJECT-TYPE
    SYNTAX      SyncTimingType
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The timing domain (freq/phase/tod) that this protection group belongs to."
    ::= { cienaCesSyncInputProtectionGroupEntry 11 }

cienaCesInputPGOperationalQualityLevel OBJECT-TYPE
    SYNTAX      SsmStratumLevel
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Operational Quality Level of the protection group."
    ::= { cienaCesSyncInputProtectionGroupEntry 12 }

--
-- SyncInputProtectionUnitTable
--

cienaCesSyncInputProtectionUnitTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF CienaCesSyncInputProtectionUnitEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table of protection units for input timing reference."
    ::= {  cienaCesTimeSyncObjects 6 }

cienaCesSyncInputProtectionUnitEntry OBJECT-TYPE
    SYNTAX      CienaCesSyncInputProtectionUnitEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry in this table represents information on a protection
         unit for input timing reference."
    INDEX       { cienaCesInputPUEntityId }
    ::= { cienaCesSyncInputProtectionUnitTable 1 }

CienaCesSyncInputProtectionUnitEntry ::= SEQUENCE {
        cienaCesInputPUEntityId                  Integer32,
        cienaCesInputPUEntityName                DisplayString,
        cienaCesInputPUPGEntityName              DisplayString,
        cienaCesInputPUTimingInterfaceName       DisplayString,
        cienaCesInputPUTimingInterfaceProtocol   SyncInterfaceProtocol,
        cienaCesInputPUUserPriority              Unsigned32,
        cienaCesInputPUOperationalQL             SsmStratumLevel,
        cienaCesInputPUForcedQL                  SsmStratumLevel,
        cienaCesInputPUReceivedQL                SsmStratumLevel,
        cienaCesInputPUSsmEnabled                INTEGER,
        cienaCesInputPUOperationalStatus         SyncRefOperationalStatus,
        cienaCesInputPUBITSSignalMode            SyncBITSSignalMode,
        cienaCesInputPUBITSSignalFormat          SyncBITSSignalFormat,
        cienaCesInputPUBITSSignalEncoding        SyncBITSSignalEncoding,
        cienaCesInputPUUserOverridePriority      Unsigned32,
        cienaCesInputPUPTPEncapType              SyncPTPEncapType,
        cienaCesInputPUGPSClockMode              SyncTimingType,
        cienaCesInputPUGPSFreqClock              SyncGPSFreqClock,
        cienaCesInputPUBITSSignalSsmLocation     INTEGER
        }

 cienaCesInputPUEntityId OBJECT-TYPE
    SYNTAX      Integer32 (1..48)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The unique identifier of this input protection unit."
    ::= { cienaCesSyncInputProtectionUnitEntry 1 }

 cienaCesInputPUEntityName OBJECT-TYPE
    SYNTAX      DisplayString (SIZE (1..31))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The unique name of this input protection unit."
    ::= { cienaCesSyncInputProtectionUnitEntry 2 }

 cienaCesInputPUPGEntityName OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The identifier of the input protection group(s) which this input
         protection unit belongs to."
    ::= { cienaCesSyncInputProtectionUnitEntry 3 }

 cienaCesInputPUTimingInterfaceName OBJECT-TYPE
    SYNTAX      DisplayString (SIZE (1..31))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The interface name of this input protection unit."
    ::= { cienaCesSyncInputProtectionUnitEntry 4 }

 cienaCesInputPUTimingInterfaceProtocol OBJECT-TYPE
    SYNTAX      SyncInterfaceProtocol
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The interface protocol of this input protection unit."
    ::= { cienaCesSyncInputProtectionUnitEntry 5 }

 cienaCesInputPUUserPriority OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The user configured priority of this input protection unit."
    ::= { cienaCesSyncInputProtectionUnitEntry 6 }

 cienaCesInputPUOperationalQL OBJECT-TYPE
    SYNTAX      SsmStratumLevel
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Operational clock quality level of this input protection unit."
    ::= { cienaCesSyncInputProtectionUnitEntry 7 }

 cienaCesInputPUForcedQL OBJECT-TYPE
    SYNTAX      SsmStratumLevel
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "User configured clock quality level that this input protection unit
         is forced to operate at."
    ::= { cienaCesSyncInputProtectionUnitEntry 8 }

 cienaCesInputPUReceivedQL OBJECT-TYPE
    SYNTAX      SsmStratumLevel
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Actual received clock quality level of this input protection unit."
    ::= { cienaCesSyncInputProtectionUnitEntry 9 }

 cienaCesInputPUSsmEnabled OBJECT-TYPE
    SYNTAX      INTEGER
                {
                   unknown(1),
                   disabled(2),
                   enabled(3)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Enable/disable reading of actual received clock quality level for 
         this input protection unit."
    ::= { cienaCesSyncInputProtectionUnitEntry 10 }

 cienaCesInputPUOperationalStatus OBJECT-TYPE
    SYNTAX      SyncRefOperationalStatus
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Operational status of this input protection unit."
    ::= { cienaCesSyncInputProtectionUnitEntry 11 }

 cienaCesInputPUBITSSignalMode OBJECT-TYPE
    SYNTAX      SyncBITSSignalMode
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "BITS Signal Mode, set if BITS signal is used as a protection unit."
    ::= { cienaCesSyncInputProtectionUnitEntry 12 }

 cienaCesInputPUBITSSignalFormat OBJECT-TYPE
    SYNTAX      SyncBITSSignalFormat
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "BITS Signal Format, set if BITS signal is used as a protection unit."
    ::= { cienaCesSyncInputProtectionUnitEntry 13 }

 cienaCesInputPUBITSSignalEncoding OBJECT-TYPE
    SYNTAX      SyncBITSSignalEncoding
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "BITS Signal encoding, set if BITS signal is used as a protection unit."
    ::= { cienaCesSyncInputProtectionUnitEntry 14 }

 cienaCesInputPUUserOverridePriority OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The user configured override-priority of this input protection unit."
    ::= { cienaCesSyncInputProtectionUnitEntry 15 }

 cienaCesInputPUPTPEncapType OBJECT-TYPE
    SYNTAX      SyncPTPEncapType
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "PTP Encapsulation Type, set if a PTP input is used as a protection unit."
    ::= { cienaCesSyncInputProtectionUnitEntry 16 }

 cienaCesInputPUGPSClockMode OBJECT-TYPE
    SYNTAX      SyncTimingType
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "GPS clock mode, set if a GPS input is used as a protection unit."
    ::= { cienaCesSyncInputProtectionUnitEntry 17 }

 cienaCesInputPUGPSFreqClock OBJECT-TYPE
    SYNTAX      SyncGPSFreqClock
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "GPS frequency clock, set if a GPS input is used as a protection unit and the 
        cienaCesInputPUGPSClockMode is set to frequency."
    ::= { cienaCesSyncInputProtectionUnitEntry 18 }

 cienaCesInputPUBITSSignalSsmLocation OBJECT-TYPE
    SYNTAX      INTEGER
                {
                   unknown(1),
                   sa4(2),
                   sa5(3),
                   sa6(4),
                   sa7(5),
                   sa8(6)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "BITS Signal Ssm Location, set if BITS signal is used as an input reference."
    ::= { cienaCesSyncInputProtectionUnitEntry 19 }

--
-- SyncOutputTable
--

cienaCesSyncOutputTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF CienaCesSyncOutputEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A table of output timing references."
    ::= {  cienaCesTimeSyncObjects 7 }

cienaCesSyncOutputEntry OBJECT-TYPE
    SYNTAX      CienaCesSyncOutputEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry in this table represents information for an output 
         timing reference."
    INDEX       { cienaCesOutputEntityId }
    ::= { cienaCesSyncOutputTable 1 }

CienaCesSyncOutputEntry ::= SEQUENCE {
        cienaCesOutputEntityId                  Integer32,
        cienaCesOutputEntityName                DisplayString,
        cienaCesOutputTimingInterfaceName       DisplayString,
        cienaCesOutputTimingInterfaceProtocol   SyncInterfaceProtocol,
        cienaCesOutputOperationalQL             SsmStratumLevel,
        cienaCesOutputOperationalStatus         SyncRefOperationalStatus,
        cienaCesOutputBITSSignalMode            SyncBITSSignalMode,
        cienaCesOutputBITSSignalFormat          SyncBITSSignalFormat,
        cienaCesOutputBITSSignalEncoding        SyncBITSSignalEncoding,
        cienaCesOutputBITSSignalLineBuildout    INTEGER,
        cienaCesOutputBITSSignalSsmLocation     INTEGER,
        cienaCesOutputGPSClockMode              SyncTimingType,
        cienaCesOutputGPSFreqClock              SyncGPSFreqClock,
        cienaCesOutputPTPEncapType              SyncPTPEncapType
        }

 cienaCesOutputEntityId OBJECT-TYPE
    SYNTAX      Integer32 (1..48)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The unique identifier of this output reference entity."
    ::= { cienaCesSyncOutputEntry 1 }

 cienaCesOutputEntityName OBJECT-TYPE
    SYNTAX      DisplayString (SIZE (1..31))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The unique name of this output reference entity."
    ::= { cienaCesSyncOutputEntry 2 }

 cienaCesOutputTimingInterfaceName OBJECT-TYPE
    SYNTAX      DisplayString (SIZE (1..31))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The interface name of this output reference."
    ::= { cienaCesSyncOutputEntry 3 }

 cienaCesOutputTimingInterfaceProtocol OBJECT-TYPE
    SYNTAX      SyncInterfaceProtocol
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The interface protocol of this output reference."
    ::= { cienaCesSyncOutputEntry 4 }

 cienaCesOutputOperationalQL OBJECT-TYPE
    SYNTAX      SsmStratumLevel
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Operational clock quality level of this output reference."
    ::= { cienaCesSyncOutputEntry 5 }

 cienaCesOutputOperationalStatus OBJECT-TYPE
    SYNTAX      SyncRefOperationalStatus
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Operational status of this output reference."
    ::= { cienaCesSyncOutputEntry 6 }

 cienaCesOutputBITSSignalMode OBJECT-TYPE
    SYNTAX      SyncBITSSignalMode
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "BITS Signal Mode, set if BITS signal is used as an output reference."
    ::= { cienaCesSyncOutputEntry 7 }

 cienaCesOutputBITSSignalFormat OBJECT-TYPE
    SYNTAX      SyncBITSSignalFormat
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "BITS Signal Format, set if BITS signal is used as an output reference."
    ::= { cienaCesSyncOutputEntry 8 }

 cienaCesOutputBITSSignalEncoding OBJECT-TYPE
    SYNTAX      SyncBITSSignalEncoding
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "BITS Signal encoding, set if BITS signal is used as an output reference."
    ::= { cienaCesSyncOutputEntry 9 }

 cienaCesOutputBITSSignalLineBuildout OBJECT-TYPE
    SYNTAX      INTEGER
                {
                   unknown(1),
                   lbo133(2),
                   lbo266(3),
                   lbo399(4),
                   lbo533(5),
                   lbo655(6)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "BITS Signal Line Buildout, set if BITS signal is used as an output reference."
    ::= { cienaCesSyncOutputEntry 10 }

 cienaCesOutputBITSSignalSsmLocation OBJECT-TYPE
    SYNTAX      INTEGER
                {
                   unknown(1),
                   sa4(2),
                   sa5(3),
                   sa6(4),
                   sa7(5),
                   sa8(6)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "BITS Signal Ssm Location, set if BITS signal is used as an output reference."
    ::= { cienaCesSyncOutputEntry 11 }

 cienaCesOutputGPSClockMode OBJECT-TYPE
    SYNTAX      SyncTimingType
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "GPS clock mode, set if a GPS signal is used as an output reference."
    ::= { cienaCesSyncOutputEntry 12 }

 cienaCesOutputGPSFreqClock OBJECT-TYPE
    SYNTAX      SyncGPSFreqClock
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "GPS frequency clock, set if a GPS signal is used as an output reference and the 
        cienaCesOutputGPSClockMode is set to frequency."
    ::= { cienaCesSyncOutputEntry 13}

  cienaCesOutputPTPEncapType OBJECT-TYPE
    SYNTAX      SyncPTPEncapType
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "PTP Encapsulation Type, set if a PTP output is used as an output reference."
    ::= { cienaCesSyncOutputEntry 14 }
--
-- cienaCesSyncPTPConfig 
--

 cienaCesSyncPTPConfig       OBJECT IDENTIFIER ::= { cienaCesTimeSyncObjects 8 }
 cienaCesSyncPTPGlobalConfig OBJECT IDENTIFIER ::= { cienaCesSyncPTPConfig 1 }
 cienaCesSyncPTPInputConfig  OBJECT IDENTIFIER ::= { cienaCesSyncPTPConfig 2 }
 cienaCesSyncPTPOutputConfig OBJECT IDENTIFIER ::= { cienaCesSyncPTPConfig 3 }
 
--
-- cienaCesSyncPTPGlobalConfig 
--

 cienaCesSyncPTPAddrMode OBJECT-TYPE
    SYNTAX      INTEGER
                {
                   unknown(1),
                   unicast(2),
                   multicast(3)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "PTP Address Mode."
    ::= { cienaCesSyncPTPGlobalConfig 1 }

 cienaCesSyncPTPTagPriority OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "PTP tag priority"
    ::= { cienaCesSyncPTPGlobalConfig 2 }

 cienaCesSyncPTPProtocolVersion OBJECT-TYPE
    SYNTAX      INTEGER
                {
                   unknown(1),
                   v2(2)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "PTP Protocol Version."
    ::= { cienaCesSyncPTPGlobalConfig 3 }

 cienaCesSyncPTPProfileVersion OBJECT-TYPE
    SYNTAX      INTEGER
                {
                   unknown(1),
                   version1dot0(2)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "PTP Profile Version."
    ::= { cienaCesSyncPTPGlobalConfig 4 }

 cienaCesSyncPTPProfileIdentifier OBJECT-TYPE
    SYNTAX      MacAddress
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "PTP profile identifier address."
    ::= { cienaCesSyncPTPGlobalConfig 5 }

 cienaCesSyncPTPDomainNumber OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "PTP domain number."
    ::= { cienaCesSyncPTPGlobalConfig 6 }

 cienaCesSyncPTPClockType OBJECT-TYPE
    SYNTAX      INTEGER
                {
                   unknown(1),
                   ocslave(2),
                   bc(3)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "PTP Clock Type."
    ::= { cienaCesSyncPTPGlobalConfig 7 }

 cienaCesSyncPTPClockID OBJECT-TYPE
    SYNTAX      DisplayString (SIZE (1..31))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "PTP clock identifier."
    ::= { cienaCesSyncPTPGlobalConfig 8 }

 cienaCesSyncPTPDscp OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "PTP DSCP."
    ::= { cienaCesSyncPTPGlobalConfig 9 }

--
-- cienaCesSyncPTPInputConfig 
--

 cienaCesSyncPTPInputUnicastReqDuration OBJECT-TYPE
     SYNTAX      Unsigned32
     MAX-ACCESS  read-only
     STATUS      current
     DESCRIPTION
         "PTP input unicast request duration in seconds."
    ::= { cienaCesSyncPTPInputConfig 1 }

 cienaCesSyncPTPInputAnnounceRxLossNum OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "PTP input announce Rx loss num (announce intervals)."
    ::= { cienaCesSyncPTPInputConfig 2 }

 cienaCesSyncPTPInputAnnounceTxRateReq OBJECT-TYPE
    SYNTAX      SyncPTPRatePps
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "PTP input announce Tx rate request (pps)."
    ::= { cienaCesSyncPTPInputConfig 3 }

 cienaCesSyncPTPInputSyncTxRateReq OBJECT-TYPE
    SYNTAX      SyncPTPRatePps
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "PTP input sync Tx rate request (pps)."
    ::= { cienaCesSyncPTPInputConfig 4 }

 cienaCesSyncPTPInputDelayReqTxRate OBJECT-TYPE
    SYNTAX      SyncPTPRatePps
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "PTP input delay request Tx rate (pps)."
    ::= { cienaCesSyncPTPInputConfig 5 }

--
-- cienaCesSyncPTPOutputConfig 
--

 cienaCesSyncPTPOutputMaxSlaveSessions OBJECT-TYPE
     SYNTAX      Unsigned32
     MAX-ACCESS  read-only
     STATUS      current
     DESCRIPTION
         "Maximum number of allowed PTP slave sessions for PTP outputs."
    ::= { cienaCesSyncPTPOutputConfig 1 }

 cienaCesSyncPTPOutputTimestampMode OBJECT-TYPE
    SYNTAX      INTEGER
                {
                   unknown(1),
                   onestep(2),
                   twostep(3)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "PTP timestamp mode."
    ::= { cienaCesSyncPTPOutputConfig 2 }

--
-- cienaCesSyncGPSConfig 
--

 cienaCesSyncGPSConfig       OBJECT IDENTIFIER ::= { cienaCesTimeSyncObjects 9 }
 cienaCesSyncGPSOutputConfig OBJECT IDENTIFIER ::= { cienaCesSyncGPSConfig 1 }
 
--
-- cienaCesSyncGPSOutputConfig 
--

 cienaCesSyncGPSOutput1ppsPulseWidth OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The 1pps pulse width, in microseconds, for GPS output references (applicable to phase)."
    ::= { cienaCesSyncGPSOutputConfig 1 }

--
-- cienaCesSyncModuleSlotClockStatus
--

 cienaCesSyncModuleSlotClockStatus OBJECT-TYPE
    SYNTAX      INTEGER
                {
                   unknown(1),
                   lossoflock(2),
                   lockedtoprimaryctx(3),
                   lockedtosecondaryctx(4)
                }
    MAX-ACCESS  accessible-for-notify
    STATUS      current
    DESCRIPTION
        "Lock status of module slot."
    ::= { cienaCesTimeSyncObjects 11 }

 --
 -- notifications
 --

 cienaCesSyncInputPUStateChangeNotification NOTIFICATION-TYPE
    OBJECTS {  
               cienaGlobalSeverity,
               cienaGlobalMacAddress,       
               cienaCesInputPUEntityName,
               cienaCesInputPUPGEntityName,
               cienaCesInputPUTimingInterfaceName,
               cienaCesInputPUTimingInterfaceProtocol,
               cienaCesInputPUOperationalStatus
            }
    STATUS  current
    DESCRIPTION
        "Sent when a configured timing reference transitions states." 
    ::= { cienaCesTimeSyncMIBNotifications 1 }
 
 cienaCesSyncInputProtectionGroupStateChangeNotification NOTIFICATION-TYPE
    OBJECTS {  
               cienaGlobalSeverity,
               cienaGlobalMacAddress,       
               cienaCesInputPGEntityName,
               cienaCesInputPGOperationalStatus,
               cienaCesInputPGSelectedReference
            }
    STATUS  current
    DESCRIPTION
        "Sent when a configured protection-group transitions states." 
    ::= { cienaCesTimeSyncMIBNotifications 2 }
 
cienaCesSyncModuleSlotClockStateChangeNotification NOTIFICATION-TYPE
    OBJECTS {  
               cienaGlobalSeverity,
               cienaGlobalMacAddress,       
               cienaCesModuleSlotName,
               cienaCesSyncModuleSlotClockStatus
            }
    STATUS  current
    DESCRIPTION
        "Sent when a slot other than the primary CTX experiences a timing state change. Only applicable in SAOS 8.x." 
    ::= { cienaCesTimeSyncMIBNotifications 3 }
 
  END
 
 --
 -- CIENA-CES-TIME-SYNC-MIB
 --
 